{"id":3144,"date":"2026-01-30T00:00:00","date_gmt":"2026-01-29T23:00:00","guid":{"rendered":"https:\/\/kunden.weissblaumedia.de\/microconsult\/2018\/03\/20\/mg_aurix-safety\/"},"modified":"2026-06-17T13:16:57","modified_gmt":"2026-06-17T11:16:57","slug":"mg_autrix-safety","status":"publish","type":"post","link":"https:\/\/www.microconsult.de\/en\/mg_aurix-safety\/","title":{"rendered":"Safety concepts for Aurix microcontrollers"},"content":{"rendered":"<p><strong>Software and hardware developers appreciate the Safety Management Unit of the Aurix microcontrollers as an independent unit for error handling.<\/strong><\/p>\n<p>New regulations related to functional safety in both industry and the automotive sector are further driving the adoption of multicore systems like Aurix. On the one hand, manufacturers are responding to customer demands for greater integration to reduce system complexity and costs. On the other hand, this leads to increased efficiency in the implementation of safety-certified systems (IEC 65108, ISO 26262). Together with requirements from software specifications (e.g., AUTOSAR), many new opportunities for the use of multicore systems are currently emerging.<\/p>\n<p><!--more--><\/p>\n<h4>Lock-Step kernels automatically detect single-event effects.<\/h4>\n<p>Some embedded projects may require a strict separation and division into safety-relevant and non-relevant application units. ISO 26262, in particular, offers a good way to effectively utilize multicore systems with its ASIL decomposition concept. Appropriate partitioning helps to achieve this on multicore platforms with a high degree of efficiency.<\/p>\n<p>However, fundamental safety principles such as redundancy remain relevant. These are implemented at the core level through resource duplication. So-called lock-step cores execute the same instructions as the &quot;normal&quot; core, albeit with a delay of a few clock cycles. If the results differ, a corresponding alarm signal is triggered, initiating the appropriate response. Single-event effects are automatically detected via this mechanism.<\/p>\n<h4>Easily configure write access to resources<\/h4>\n<p>Access control for shared resources is becoming increasingly important in such systems. If access is to be possible for all system elements in principle, performance must not suffer. If the other cores are slowed down over a long period, regulations and restrictions should be implemented as needed. For this reason, manufacturers have assigned identification numbers to the different cores and other authorized participants (e.g., DMA). Resources can be configured to allow write access only from explicitly authorized participants. Memory access also falls into this category. However, these are so critical that separate protection units are often implemented for them.<\/p>\n<h4>Safety Management Unit as an independent unit for fault handling<\/h4>\n<p>All potential alarms that can be triggered by such protective mechanisms are collected in a dedicated unit and processed further. In Aurix, this is achieved using the so-called Safety Management Unit. It serves as a central collection point for all safety-critical alarms. Depending on the configuration, it executes various error handling procedures.<\/p>\n<p>Since such error handling should naturally not be performed on a potentially faulty unit (i.e., the processing core), the SMU is designed as an independent unit. Alarms can be handled individually, but this may not always lead to a successful outcome (safe state or partial shutdown, etc.).<\/p>\n<p>For this purpose, the SMU also provides the option of a backup plan. This is linked to a timer running in the background, which triggers a system reset when it expires.<\/p>\n<p><strong>Bring your Aurix knowledge up to date and learn about modern safety concepts in the specially developed MicroConsult seminars.<a href=\"https:\/\/www.microconsult.de\/en\/training-consulting\/trainings\/tricore-aurix\/aaaajzs\/\" target=\"_blank\" rel=\"noopener\"> Aurix multicore microcontroller<\/a> as well as in special <a href=\"https:\/\/www.microconsult.de\/en\/training-consulting\/trainings\/sicherheit-safety-und-security\/aaaakdz\/\" target=\"_blank\" rel=\"noopener\">Safety training<\/a>. Register now!<\/strong><\/p>\n<h4>Further information<\/h4>\n<p><a href=\"https:\/\/www.microconsult.de\/en\/microcontroller\/\" target=\"_blank\" rel=\"noopener\"><strong>MicroConsult expertise on the topic of microcontrollers<\/strong> <\/a><\/p>\n<p><strong><a href=\"https:\/\/www.microconsult.de\/en\/training-consulting\/trainings\/multicore-programmierung\/aaaakac\/\" target=\"_blank\" rel=\"noopener\">MicroConsult Training &amp; Coaching on the topic of multicore<\/a><\/strong><\/p>\n<p><a href=\"https:\/\/www.microconsult.de\/en\/training-consulting\/trainings\/sicherheit-safety-und-security\/aaaakdz\/\" target=\"_blank\" rel=\"noopener\"><strong>MicroConsult Training &amp; Coaching on the topic of Safety &amp; Security<\/strong><\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Soft- und Hardwareentwickler wissen die Safety Management Unit der Aurix-Mikrocontroller als eigenst\u00e4ndige Einheit f\u00fcr Fehlerbehandlungen zu sch\u00e4tzen. Neue Regeln im Zusammenhang mit funktionaler Sicherheit sowohl in der Industrie als auch im Automobilbereich treiben die Verbreitung von Multicore-Systemen wie Aurix weiter voran. Einerseits reagieren die Hersteller damit auf Kundenw\u00fcnsche nach h\u00f6herer Integration, um die Komplexit\u00e4t und [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":3145,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","inline_featured_image":false,"footnotes":""},"categories":[21,51],"tags":[139,42,22,23,26,140,13],"class_list":["post-3144","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mikrocontroller","category-qualitaet_und_sicherheit","tag-aurix","tag-embedded","tag-mikrocontroller","tag-multicore","tag-safety","tag-safety-management-unit","tag-security"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Safety-Konzepte f\u00fcr Aurix-Mikrocontroller - MicroConsult Academy GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.microconsult.de\/en\/mg_autrix-safety\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Safety-Konzepte f\u00fcr Aurix-Mikrocontroller - MicroConsult Academy GmbH\" \/>\n<meta property=\"og:description\" content=\"Soft- und Hardwareentwickler wissen die Safety Management Unit der Aurix-Mikrocontroller als eigenst\u00e4ndige Einheit f\u00fcr Fehlerbehandlungen zu sch\u00e4tzen. Neue Regeln im Zusammenhang mit funktionaler Sicherheit sowohl in der Industrie als auch im Automobilbereich treiben die Verbreitung von Multicore-Systemen wie Aurix weiter voran. Einerseits reagieren die Hersteller damit auf Kundenw\u00fcnsche nach h\u00f6herer Integration, um die Komplexit\u00e4t und [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.microconsult.de\/en\/mg_autrix-safety\/\" \/>\n<meta property=\"og:site_name\" content=\"MicroConsult Academy GmbH\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-29T23:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-17T11:16:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.microconsult.de\/wp-content\/uploads\/2025\/07\/safety-aurix-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"849\" \/>\n\t<meta property=\"og:image:height\" content=\"566\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Marcus G\u00f6\u00dfler\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marcus G\u00f6\u00dfler\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/\"},\"author\":{\"name\":\"Marcus G\u00f6\u00dfler\",\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/#\\\/schema\\\/person\\\/f3fb5703cf4619b776489b3fe63181d4\"},\"headline\":\"Safety-Konzepte f\u00fcr Aurix-Mikrocontroller\",\"datePublished\":\"2026-01-29T23:00:00+00:00\",\"dateModified\":\"2026-06-17T11:16:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/\"},\"wordCount\":525,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.microconsult.de\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/safety-aurix-1.jpg\",\"keywords\":[\"Aurix\",\"embedded\",\"Mikrocontroller\",\"Multicore\",\"Safety\",\"Safety Management Unit\",\"Security\"],\"articleSection\":[\"Mikrocontroller\",\"Qualit\u00e4t und Sicherheit\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/\",\"url\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/\",\"name\":\"Safety-Konzepte f\u00fcr Aurix-Mikrocontroller - MicroConsult Academy GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.microconsult.de\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/safety-aurix-1.jpg\",\"datePublished\":\"2026-01-29T23:00:00+00:00\",\"dateModified\":\"2026-06-17T11:16:57+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/#\\\/schema\\\/person\\\/f3fb5703cf4619b776489b3fe63181d4\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.microconsult.de\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/safety-aurix-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.microconsult.de\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/safety-aurix-1.jpg\",\"width\":849,\"height\":566,\"caption\":\"Toy plastic forklift hold block Y to compose and fulfill wording safety on wood background\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/mg_aurix-safety\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.microconsult.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Safety-Konzepte f\u00fcr Aurix-Mikrocontroller\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/#website\",\"url\":\"https:\\\/\\\/www.microconsult.de\\\/\",\"name\":\"MicroConsult Academy GmbH\",\"description\":\"Professionelle Schulungen, Beratung und Projektunterst\u00fctzung\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.microconsult.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.microconsult.de\\\/#\\\/schema\\\/person\\\/f3fb5703cf4619b776489b3fe63181d4\",\"name\":\"Marcus G\u00f6\u00dfler\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7990a03a3ce566dafd510764639d3deb9e5ba17a63b6d8132cd814fcd101f4b8?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7990a03a3ce566dafd510764639d3deb9e5ba17a63b6d8132cd814fcd101f4b8?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7990a03a3ce566dafd510764639d3deb9e5ba17a63b6d8132cd814fcd101f4b8?s=96&d=mm&r=g\",\"caption\":\"Marcus G\u00f6\u00dfler\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Safety concepts for Aurix microcontrollers - MicroConsult Academy GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.microconsult.de\/en\/mg_autrix-safety\/","og_locale":"en_GB","og_type":"article","og_title":"Safety-Konzepte f\u00fcr Aurix-Mikrocontroller - MicroConsult Academy GmbH","og_description":"Soft- und Hardwareentwickler wissen die Safety Management Unit der Aurix-Mikrocontroller als eigenst\u00e4ndige Einheit f\u00fcr Fehlerbehandlungen zu sch\u00e4tzen. Neue Regeln im Zusammenhang mit funktionaler Sicherheit sowohl in der Industrie als auch im Automobilbereich treiben die Verbreitung von Multicore-Systemen wie Aurix weiter voran. Einerseits reagieren die Hersteller damit auf Kundenw\u00fcnsche nach h\u00f6herer Integration, um die Komplexit\u00e4t und [&hellip;]","og_url":"https:\/\/www.microconsult.de\/en\/mg_autrix-safety\/","og_site_name":"MicroConsult Academy GmbH","article_published_time":"2026-01-29T23:00:00+00:00","article_modified_time":"2026-06-17T11:16:57+00:00","og_image":[{"width":849,"height":566,"url":"https:\/\/www.microconsult.de\/wp-content\/uploads\/2025\/07\/safety-aurix-1.jpg","type":"image\/jpeg"}],"author":"Marcus G\u00f6\u00dfler","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Marcus G\u00f6\u00dfler","Estimated reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/#article","isPartOf":{"@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/"},"author":{"name":"Marcus G\u00f6\u00dfler","@id":"https:\/\/www.microconsult.de\/#\/schema\/person\/f3fb5703cf4619b776489b3fe63181d4"},"headline":"Safety-Konzepte f\u00fcr Aurix-Mikrocontroller","datePublished":"2026-01-29T23:00:00+00:00","dateModified":"2026-06-17T11:16:57+00:00","mainEntityOfPage":{"@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/"},"wordCount":525,"commentCount":0,"image":{"@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/#primaryimage"},"thumbnailUrl":"https:\/\/www.microconsult.de\/wp-content\/uploads\/2025\/07\/safety-aurix-1.jpg","keywords":["Aurix","embedded","Mikrocontroller","Multicore","Safety","Safety Management Unit","Security"],"articleSection":["Mikrocontroller","Qualit\u00e4t und Sicherheit"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.microconsult.de\/mg_aurix-safety\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/","url":"https:\/\/www.microconsult.de\/mg_aurix-safety\/","name":"Safety concepts for Aurix microcontrollers - MicroConsult Academy GmbH","isPartOf":{"@id":"https:\/\/www.microconsult.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/#primaryimage"},"image":{"@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/#primaryimage"},"thumbnailUrl":"https:\/\/www.microconsult.de\/wp-content\/uploads\/2025\/07\/safety-aurix-1.jpg","datePublished":"2026-01-29T23:00:00+00:00","dateModified":"2026-06-17T11:16:57+00:00","author":{"@id":"https:\/\/www.microconsult.de\/#\/schema\/person\/f3fb5703cf4619b776489b3fe63181d4"},"breadcrumb":{"@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.microconsult.de\/mg_aurix-safety\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/#primaryimage","url":"https:\/\/www.microconsult.de\/wp-content\/uploads\/2025\/07\/safety-aurix-1.jpg","contentUrl":"https:\/\/www.microconsult.de\/wp-content\/uploads\/2025\/07\/safety-aurix-1.jpg","width":849,"height":566,"caption":"Toy plastic forklift hold block Y to compose and fulfill wording safety on wood background"},{"@type":"BreadcrumbList","@id":"https:\/\/www.microconsult.de\/mg_aurix-safety\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.microconsult.de\/"},{"@type":"ListItem","position":2,"name":"Safety-Konzepte f\u00fcr Aurix-Mikrocontroller"}]},{"@type":"WebSite","@id":"https:\/\/www.microconsult.de\/#website","url":"https:\/\/www.microconsult.de\/","name":"MicroConsult Academy GmbH","description":"Professional training, consulting and project support","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.microconsult.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.microconsult.de\/#\/schema\/person\/f3fb5703cf4619b776489b3fe63181d4","name":"Marcus G\u00f6\u00dfler","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/7990a03a3ce566dafd510764639d3deb9e5ba17a63b6d8132cd814fcd101f4b8?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7990a03a3ce566dafd510764639d3deb9e5ba17a63b6d8132cd814fcd101f4b8?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7990a03a3ce566dafd510764639d3deb9e5ba17a63b6d8132cd814fcd101f4b8?s=96&d=mm&r=g","caption":"Marcus G\u00f6\u00dfler"}}]}},"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/posts\/3144","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/comments?post=3144"}],"version-history":[{"count":2,"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/posts\/3144\/revisions"}],"predecessor-version":[{"id":10926,"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/posts\/3144\/revisions\/10926"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/media\/3145"}],"wp:attachment":[{"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/media?parent=3144"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/categories?post=3144"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.microconsult.de\/en\/wp-json\/wp\/v2\/tags?post=3144"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}